Gas insulated substation maintenance pdf

Operation and maintenance of a gas insulated substation a major difference between conventional air insulated substations ais and the gas insulated substations gis is that the sf6 gas insulated electrical components are. Gas insulated switchgear maintenance philosophy maintenance philosophy for gis type elk1, 2, 3 time based maintenance condition based maintenance criteria. Gas insulated substations gis have been used in power systems over the last three decades because of their high reliability, easy maintenance, small ground space requirement, etc. They require protection against atmospheric pollution and moisture,noiseless operation, non explosive and flame resistant,reduced maintenance, minimal radio interference, but totally enclosed sf6 gas as insulation also known as gas insulated substation is now widespread in use. This has led the utilities to adopt conditionbased maintenance of the equipments rather than usual preventive maintenance being carried out at a fixed interval of time. Pioneer and technology leader driving gis innovations. The maintenance earth switch is a slow device used to ground the high voltage conductors during maintenance schedules, in order to ensure the safety of the maintenance staff. Nov 04, 2017 the main advantage of this gas insulated substation is because of its compact size due to a high dielectric strength of the sf 6 gas.

This functional specification covers all types of substation with equipment installed for use on 2, 275 and 400 kv 50 hz systems. Fast earth switch and maintenance earth switch are the two types of earth switches used for gas insulated substation systems. And the availability and reliability of the gis substations are more compared to air insulated substations faults occurring chances of air insulated substation or conventional substations are more. Gas insulated substations high system reliability highflexibilityofitssolutionsmodularityexpandability gas insulated substations high flexibility of its solutions modularity, expandability compact space saving solutions innovative solutions devices, switchgears low life cycle costs reliable and competent partners operator, manufacturer. This article is an introduction to gasinsulated substations. Gasinsulated substations high flexibility of its solutions modularity, expandability compact space saving solutions. Gas insulated switchgear gis refers to the general equipment of a substation in a metal enclosure filled with highinsulation sf 6 gas and connected to the ground, which includes a circuit breaker, disconnecting switches, earthing switches, and peripheral devices e. This course is based on terms used in ieee and iec regulations. Gas insulated substation is employed where a where there is less space available b for high altitude substations c in terrain region d all the above. Gas insulated substation electrical substation transformer. Ge provides a full range of gas insulated substations gis for utilities and industries worldwide. The gas insulated switchgear elk04 is the ideal solution for reliable energy supply up to a rated voltage of 170 kv, a rated normal current up to 4000 a, and a rated short circuit current up to 63 ka.

Pdf maintenance method based on risk estimation for 170kv gas. Gas insulated switchgear up to 245 kv, 50 ka, 4000 a. Abb substations with gas insulated switchgear gis are unmatched when it comes to compactness, reliability, efficiency and safety, ensuring maximum power availability for utility, commercial and industrial customers. A gas insulated substation gis uses a superior dielectric gas, sf6, at moderate pressure for phasetophase and phasetoground insulation. Unified sf6 gas pressure throughout the switchgear makes simplified gas maintenance work. A gas tight barrier insulator in switchgear serve for the separation of gas compartments and prevents neighbouring switchgear parts from being affected during maintenance.

These instructions for assembly are an integral part of the product and must be stored so that they are at any time readily accessible for and can be used by persons who are to work on the switchgear. Operation and maintenance of a gas insulated substation. With gis experience spanning 50 years across a wide range of industries and applications, ge is a leader in the. The metalenclosed gasinsulated switchgear is made as to ensure the best possible relationship between design, used materials, maintenance effort and. Hand holes provide ready access to circuit breaker contacts and other key gis components for ease of inspection, maintenance, and. Air insulated substation ais air used as dielectric. Conference paper pdf available september 2015 with 743 reads. Oversees the maintenance, repair and oversees the purchase and storage of ltfsf6 it sf6 replacemen t of sf6 gas equipmen. They will compare substation safety and security using ais vs. The quality of our gas insulated switchgear is the result of a rigorous standard quality management system, which has been certified in accordance with iso 9001. Gis highvoltage gas insulated switchgear substations. Maintenance intervals are normally fixed on the basis of type of equipment and sometimes on the equipment history. Ge provides a full range of gasinsulated substations gis for utilities and industries worldwide. The portfolio includes gis solutions from 60 to 800 kv, along with secondary products to maximize switchgear and network operation.

Operation and maintenance customer training gasinsulated. Flexibility to operate in harsh climatic conditions along with easy planning of outages for service and maintenance will make its adoption favorable. Gas insulated substation authorstream presentation. Sf6 equipment maintenance, repair, and replacement and. Installation, maintenance, and end of life of a gasinsulated. This article is an introduction to gas insulated substations. Gasinsulated substations gis have been used in power systems over the last three decades because of their high reliability, easy maintenance, small ground space requirement, etc.

Sf gasinsulated switchgear maintenance of circuitbreaker elk sl. Outdoor gas insulated switchgear market size in 2016, was valued over usd 11 billion. Use of strong and big maintenance units should be able to recover gas to a resid al press re of insulated substations, gasinsulated substations, and gasinsulated lines. Gis technology originated in japan, where there was a substantial need to develop technology to make substations as compact as possible. Presented paper refers to service continuity of gas insulated substations, a topic which is also dealt in annex f of iec international standard no. Gas insulated substations gis is a compact,multicomponent assembly enclosed in a ground metallic housing in which the primary insulating medium is compressed sulphur hexafluoride sf6 gas. There are five major considerations in the differences between the two high voltage substations. Gas insulated highvoltage switchgear gis is a compact metal encapsulated switchgear consisting of highvoltage components such as circuitbreakers and disconnectors, which can be safely operated in confined spaces. A bus coupler circuit breaker is utilized in a substation for a joining the transmission line with station busbar b joining main and transfer bus in a substation. It is applicable to both openterminal air insulated ais and metalenclosed gas insulated gis substation constructions and covers equipment operated at lower voltages on the same substation site. The capacity of eot crane shall be decided based on lifting of heaviest parts of gis equipmentaccessories for erection and future maintenance purpose.

Gas insulated substation ppt pdf presentation gas insulated substations gis is a compact,multicomponent assembly enclosed in a ground metallic housing in which the primary insulating medium is compressed sulphur hexafluoride sf6 gas. Contents introduction conventional substation ais limitation of ais need for gis introduction to gis gis unique features components of gis substation advantages of gis over conventional open air. Major components you can spot while looking at hvehv gis. National grid substations technical specification ngts 2. Jul 07, 2014 a onestop, complete reference text on gas insulated substations gis, largecapacity and longdistance electricity transmission, which are of increasing importance in the power industry today. A major difference between conventional air insulated substations ais and the gas insulated substations gis is that the sf6 gas insulated electrical components are placed within an earthed, pressurized metallic container. Maintenance method based on risk estimation for 170kv gas insulated switchgear. Gas insulated substations conference 2018 in washington dc. The course location is abbs training center in zurich, switzerland. Gas insulated substation free download as powerpoint presentation. A gasinsulated substation gis uses a superior dielectric gas, sf6, at moderate pressure for phasetophase and phasetoground insulation. A gas insulated substation gis is a high voltage substation in which the major structures are contained in a sealed environment with sulfur hexafluoride gas as the insulating medium.

A major difference between conventional air insulated substations ais and the gas insulated substations gis is that the sf6 gas insulated electrical. Lsis has been a leader of development of industry and best partner to improve productivity for her customers by supplying reliable and stable energy lsis is producing gis, which is one of the major equipment used in the high voltage substation in densely cities. His the gasinsulated switchgear for indoor and outdoor use needs less than half of the space of a comparable airinsulated substation. Sf6 gas superior dielectric properties used at moderate pressure for phase to phase and phase to ground insulation preferred for voltage ratings of 72. Preliminary operation before preventive maintenance 5 preventive maintenance operation details of ais substation and gis substation 2 dr. We believe that although many gis manufacturers produce a.

They are built for an estimated service life of more than 50 years. Gis there are two terms presented in iec gas insulated switchgear and ieee gas insulated substations. Gastight barrier insulators ensure that any effect on adjacent substation components is kept to a minimum. Siemens provides a wide range of services including the supply of complete packages of highvoltage. The speakers will discuss reliability and system planning implications for gas insulated substations. Less maintenance general to meet the customers various requirements of todays substations, we, hyosung, design and manufacture a wide variety of sf 6 gas insulated switchgeargis system. For voltages up to 8kv, the pipe can be filled with dry nitrogen gas highpressure gas filled, hpgf, though synthetic. Abb is a leader in highvoltage gis technology with a. The differences between air insulated substation engineering and gas insulated substation engineering are vast. The 8dq1type his is a compact switchgear solution for a rated voltage of up to 550 kv. Lsis who has been a leader in electricity and automation in. Mv primary gasinsulated switchgear zx2 december 10, 2019 slide 11 are you looking for a safe, reliable and compact switchgear design.

Guidelines for usage of air insulated substation ais or gas. Gasinsulated switchgear up to 245 kv, 50 ka, 4000 a type 8dn9. Abstract the concept of the gas insulated switchgear gis preventive maintenance system construc tion, application examples, and new sensing technologies. Several crucial terms are for better understanding of the presented material. Introduction to gas insulated substations switchgears gis. If the switchgear is sold to new owners, they must receive this document along with the. Sulphur hexaflouride sf6 gas the primary insulating medium. Gis elk04 up to 170 kv gasinsulated switchgear abb. Gasinsulated switchgear from siemens will support you with a largely maintenancefree, stable, and tested design for maximum availability even under extreme environmental conditions. During operation, siemens gis are practically maintenancefree. A cathodic protection system is important to further protect the pipe from corrosion.

Gas insulated substation electrical substation insulator. Gas insulated switchgear market size industry growth report. The individual modules are connected in such a way that subsequent expansion or the conversion of a substation can be carried out easily. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in sf6 gas inside grounded metal enclosures. The metalenclosed gas insulated switchgear is made as to ensure the best possible relationship between design, used materials, maintenance effort and maintenance intervals. Gas insulated switchgear is used in industrial areas to fulfil highenergy demands by space saving design with a minimum of cost. It can be installed in a small space in cities or buildings. Xdge is one of the most reliable gas insulated switchgear suppliers with. The clearance required for phase to phase and phase to ground for all equipment is much lower than that required in an air insulated substation. Scribd is the worlds largest social reading and publishing site. Details advanced and basic material, accessible for both existing gis users and those planning to adopt the technology. Gasinsulated switchgear transmission products siemens.

906 15 150 577 1070 755 1 866 704 645 271 1284 966 1314 267 432 314 694 140 761 1350 595 89 1509 1520 239 1400 1327 308 75 371 415 229 1430 1422 702 1196 28 59 1027 272 199 1409 1023 674 1417